Product Details:
| Minimum Order Quantity | 5 Piece |
| Treatment Technology | Membrane Bioreactor(MBR) |
| AMC Provided | Yes |
| Application Industry | Residential & Commercial Building |
| Capacity (KLD/MLD) | 2000 KLD |
| Material Of Construction | Mild Steel |
| Feed Flow Rate(m3/day or m3/hr) | 500 m3/day |
| Water Pump Power | 2 KW |
| Automation Grade | Semi Automatic |
| Impurities To Be Removed | Oil & Grease, Dissolved Minerals |
| Space Area Required(l*b*h in Feets) | 40*20*18 |
| Deliver Type | Outside India |
| Warranty | 2 Years |
| Warranty of Core Components | 6 Months |
| Treatment Stages | Tertiary Treatment, Primary Treatment, Secondary Treatment, Preliminary Treatment |
| Air Blower Count | 2 Blowers |
| Air Blower Power | 1 KW |
| Control Module | Available |
| Service Area | Tamil Nadu, Kerala, Karnataka |
It might surprise you to know that we all drink and bathe in recycled water. The water we flush down the toilet is turned into potable water, and it is the job of sewage treatment plants to make this water fit for human consumption or release into rivers and oceans.
Wastewater from sinks, baths, washing machines, toilets and other appliances has to go somewhere. After traversing miles of sewer network, it ends up in sewage treatment plants whose job is to treat and discharge it.
Sewage treatment plants collect, treat, and discharge wastewater, providing a service essential to environmental and public health.
Without adequate treatment, sewage will leach into the environment and contaminate ecosystems. For example, sewage contains bacteria and chemicals that break down using oxygen in the water. In doing so, they use oxygen that fish and aquatic life needs to survive, so it needs treatment to preserve the ecosystem.
Returning sewage/wastewater to a specified quality for safe discharge is the most crucial role of the sewage treatment plant.
Sewage treatment plants run wastewater through multiple treatment stages. After preliminary filtration, there are three main stages of wastewater treatment (primary, secondary, and tertiary), with the third stage reserved for polishing.
Sewage enters the plant network, pushed through various screens to remove large solids and waste, with grit removed by flow attenuation. The purpose of this stage is to filter the sewage of debris, sand, grit, and large particles.
Primary stage
The primary stage involves separating solids from liquids. The sewage is pumped into sedimentation tanks, where gravity forces solids to the bottom of the tank. The water is then released, leaving behind a sludge/slurry.
The sludge is a by-product of primary treatment and can sometimes be repurposed as a fertiliser, but it requires treatment such as de-watering to stabilise it. Incineration is the most likely destination for heavily contaminated sludge.
Secondary treatment
Secondary treatment is the biological treatment stage that breaks down organic contaminants in wastewater.
The two most frequently used processes are activated sludge (aerated ponds) and filter beds (sewage tricked over aggregate), where ‘good’ bacteria in the sludge/aggregate break down the pathogens in the wastewater.
After secondary treatment, wastewater can sometimes be released, providing there’s a low risk to human and animal life and the environment.
Tertiary treatment
Wastewater is considered clean after secondary treatment, but tertiary treatment returns it to an even higher quality for release in protected waters.
The type of tertiary treatment depends on the wastewater. For example, suppose we should release wastewater into bathing or shellfish waters. In that case, it requires disinfection, and nutrients in the water, like phosphorous, must also be removed.
Types of tertiary treatment include:
Additional Information:
Product Details:
| Pore size | 0.01 - 0.1 mm |
| Membrane Materials | PVDF |
| Permeate | ABS Resin |
| Seal Material | Polyurethane |
| Element Dimensions | 571 x 1535 x 45 mm |
| Effective Membrane Area | 20.0 m2 |
| Microporous Average Aperture | 0.1 mm |
| Work Pressure | 0.02 - 0.04 MPa |
| Flow Rate | 10 - 20 l / m2h |
| Dia | 0.6 mm / 1.2 mm |
| Filtration Methods | Outside - in |
| Pipe Supports | UPVC Pipe |
Product Details:
| Minimum Order Quantity | 1 Piece |
| Material of Construction | Stainless Steel |
| Air Blower Power | 0.4 kW |
| Feed Flow Rate | 2000 m3/day |
| Air Blower Count | 2 |
| Water Pump Power | 1 kW |
Advantage of STP Tanks | MS Tank | RCC Tank | Zinc Aluminium Tank IONICS |
Algae formation | Yes | Yes | No |
Corrosion | Yes | Negligible | No |
| Dismantlable to 1/10 volume | No | No | Yes |
Expandable | No | No | Yes |
Food Grade | No | No | Yes |
Life of complete tank | 10-20 Yrs | 60-100 Yrs | 50-60 yrs |
Liquid Temperature (Summer) | Increase | Increase | Don’t Change |
Maintenance | Very High | High | Negligible |
Need Painting/Coating | Yes | Yes | No |
Relocation is possible | Difficult | Not Possible | Easy |
Weight | Heavy | Very Heavy | Light |
Product Details:
| Air Blower Power | 0.4 kW |
| Feed Flow Rate | 500 m3/day |
| Air Blower Count | 1 |
| Water Pump Power | 1 kW |
Product Details:
| Brand | Greensign |
| Capacity | 100 m3/day |
| Feed Flow Rate | 100 m3/day |
| Installation Type | Containerized Plug & Play |
| Air Blower Count | 2 |
| Secondary Treatment Type | Moving Bed Bioreactor (MBBR) |
| Air Blower Power | 0.4 kW |
| Industry | Paper Mills |
| Water Pump Power | 5 kW |
| Model | Treatment Ability(m3/h) | Air Blower Power(KW) | Water Pump Power(KW) | Area(m2) |
| cxwsz-1 | 1 | 0.55 | 0.55 | 6 |
| cxwsz-2 | 2 | 0.75 | 0.55 | 10 |
| cxwsz-3 | 3 | 1.5 | 0.55 | 14 |
| cxwsz-5 | 5 | 1.5 | 0.75 | 19 |
| cxwsz-7 | 7 | 2.2 | 0.75 | 28 |
| cxwsz-10 | 10 | 3.7 | 0.75 | 39 |
| cxwsz-15 | 15 | 5.5 | 0.75 | 58 |
| cxwsz-20 | 20 | 5.5 | 1.5 | 75 |
Product Details:
| Water Source Type | Industrial Wastewater |
| Capacity | 500 m3/day |
| Water Source | SEWAGE WATER |
| Industry | Water Treatment |
| Installation Type | Completes Civil work with Installation |
| Treatment Technique | Mixed Bed Bio Reactor |
| Manufacturing Lead Time | 30 days |
| Approximate Power Consumption | 1-10 Kw |
| Overall Dimensions | AS PER DESIGN |
| Treated Water Quality | AS PER PCB |
| Usage/Application | Industrial |
| Features | Unique |
| Air Blower Count | 2 |
| Automation Grade | Semi-Automatic |
| Secondary Treatment Type | Moving Bed Bioreactor (MBBR) |
| Treatment Stages | Preliminary Treatment |
| Impurities To Be Removed | Oil and Grease |
| Preferred Area | Tamil Nadu, Kerala and Karnataka |
Product Details:
| Phase | Single |
| Brand | Greensign |
| Automation Grade | Automatic |
| Application | Waste Water Treatment |
| Model | Treatment Ability(m3/h) | Air Blower Power(KW) | Water Pump Power(KW) | Area(m2) |
| cxwsz-1 | 1 | 0.55 | 0.55 | 6 |
| cxwsz-2 | 2 | 0.75 | 0.55 | 10 |
| cxwsz-3 | 3 | 1.5 | 0.55 | 14 |
| cxwsz-5 | 5 | 1.5 | 0.75 | 19 |
| cxwsz-7 | 7 | 2.2 | 0.75 | 28 |
| cxwsz-10 | 10 | 3.7 | 0.75 | 39 |
| cxwsz-15 | 15 | 5.5 | 0.75 | 58 |
| cxwsz-20 | 20 | 5.5 | 1.5 | 75 |
Product Details:
| Water Source | Commercial Waste Water, Industrial Effluent, Municipal Sewage |
| Treated Water Quality | GARDENING & FLUSHING PURPOSE |
| Overall Dimensions (LxBxH) in meters | AS REQUIRED |
| Approximate Power Consumption(in KW) | AS REQUIRED |
| Capacity (in litre) | UPTO 1000 m3 /hr |
| Secondary Treatment Type | AS PER DESIGN |
| Automation Grade | Semi-Automatic, Automatic, Manual |
| Capacity Inlet Flow Rate (cubic meter/hour) | 5000 m3/hour, 100 m3/hour, 2000 m3/hour, 1000 m3/hour, 10000 m3/hour, 500 m3/hour |
| Plant Type | Drinking Water Treatment Plant, Wastewater Treatment Plant, Effluent Treatment Plant, Sewage Treatment Plant |
| Treatment Stages | Tertiary Treatment, Disinfection, Preliminary Treatment, Primary Treatment, Secondary Treatment |
| Capacity | UPTO 10000 m3 / hour |
| Treatment Technique | Mixed Bed Bio Reactor, Fluidized Aerated Reactor, Clarifier |
| Feed Flow Rate (cubic-meter/day) | 1000 m3/day, 50 m3/day, 500 m3/day, 100 m3/day, 2000 m3/day |
| Industry | Pharmaceutical Industry, Distillery, Automobile, Paper Mills, Slaughter House, Leather Industry, Sugar Industry, Dairy Industry, Chemical/Petroleum Industry |
| Sludge Yield | yes |
| Applicable Industry | Hospital, Automobile, Chemical/Petroleum, Pharmaceutical, Slaughter House |
| Installation Type | Prefabricated, Containerized Plug & Play, Complete Civil work with Installation |
| Type | Sewage Treatment, Water Purification for Drinking, Effluent Treatment, Waste Water Treatment |
| Voltage | 440V |
| Condition | Refurbished |
| Frequency | AS REQUIRED |
| Air Blower Count | 2 |
| Power Source | AC |
| Manufacturing Lead Time | AS REQUIRED |
| Control Module | Control Module Available |
| Number of Filtration Passes | AS REQUIRED |
| Max Water Recovery Rate | AS PER DESIGN |
| Control Panel | YES |
| Weight | AS PER DESIGN |
| Phase | 3 PHASE |
| Warranty | 1 YEAR |
| Approximate Order Value | AS PER DESIGN |
| Water Pump Power | AS PER DESIGN |
| Certifications | ISO 9001 |
| Size | as required |
| Aeration Chamber Volume | AS PER DESIGN |
| Application | water and waste water treatment |
| Air Blower Power | AS PER DESIGN |
| Air flow Rate | AS PER DESIGN |
| Brand | GREENSIGN |
| Anti-Corrosion Treatment | AS PER DESIGN |
| Material | CIVIL / FABRICATION BASED |
| End use of Treated Water | CUSTOMERS REQUIRMENT |
| Equalization Chamber Volume | AS PER DESIGN |
| Feed Flow Rate | AS PER DESIGN |
| Filtration Grade | AS PER DESIGN |
| Filtration System | AS PER DESIGN |
| Flash mixers flow rate | AS PER DESIGN |
| Gate Thickness | AS PER DESIGN |
| Number of flocculators | AS PER DESIGN |
| Oxygen Requirement | AS PER DESIGN |
| Retention Time | AS PER DESIGN |
| Sewage Throughput | AS PER DESIGN |
| Sludge Holding Chamber Volume | AS PER DESIGN |
| Treatment Capacity | AS PER DESIGN |
| Volume | AS PER DESIGN |
Features:
Product Details:
| Water Source | Borewell Water |
| Type | Mineral Removal |
| Automation Grade | Semi-Automatic |
| Capacity | 500 m3/day |